1769-AENTR EtherNet Adapter Overview

The 1769-AENTR EtherNet Adapter is a Compact I/O module. It functions as an EtherNet/IP distributed I/O system, offering capabilities to reduce I/O spares and integrate with CompactLogix. This essential adapter is available from suppliers like Routeco.

Product Identification: Compact I/O 1769-AENTR EtherNet Adapter

The 1769-AENTR is precisely identified as a Compact I/O EtherNet Adapter, a key component within the realm of industrial automation. This specific designation, “1769-AENTR,” firmly places it within Rockwell Automation’s extensive product portfolio, particularly for Compact I/O modules designed for efficiency and integration. Its fundamental identity revolves around its function as an EtherNet/IP distributed I/O system, engineered to provide robust communication and expandable input/output capabilities for diverse control architectures.

The “Compact I/O” aspect of its identification underscores its suitability for applications where space optimization is crucial, delivering powerful functionality in a smaller footprint. It is consistently found within the CompactLogix ⏤ Medium Systems section of product listings, which clearly delineates its target application environment. Furthermore, the 1769-AENTR is recognized as part of a wider family of EtherNet/IP Adapters, alongside models like the 1734-AENT and 1734-AENTR. This familial grouping emphasizes its adherence to common networking standards and its role in facilitating high-speed, reliable data exchange across industrial networks, making its identification critical for system design and implementation.

Primary Function: EtherNet/IP Distributed I/O System

The 1769-AENTR’s primary function is to serve as a crucial EtherNet/IP distributed I/O system. This adapter facilitates seamless communication, allowing CompactLogix controllers to extend their control capabilities over a network. By acting as a distributed I/O system, it empowers users to strategically place I/O modules closer to sensors and actuators, thereby minimizing wiring complexity and installation costs. Its design focuses on leveraging the robust EtherNet/IP protocol, a standard for industrial automation, ensuring high-speed data exchange and reliable performance.

This capability is particularly vital for implementing Logix solutions in low to medium-level control applications, where efficient and scalable I/O management is paramount. The 1769-AENTR enables the integration of various Compact I/O modules into a unified network architecture, enhancing flexibility and modularity. Furthermore, its role as a distributed system contributes significantly to reducing the need for extensive I/O spares, streamlining inventory and maintenance efforts. It is an integral part of the broader EtherNet/IP adapter family, ensuring compatibility and interoperability within a wide range of industrial automation systems, thus optimizing operational efficiency and system expansion.

Market Availability: Routeco Allen-Bradley 1769-AENTR

The Allen-Bradley 1769-AENTR EtherNet Adapter is readily accessible through established industrial automation distributors. Notably, Routeco prominently features this crucial component, making it available for purchase directly from their dedicated CompactLogix ⏤ Medium Systems section. This specialized availability ensures customers can easily locate and acquire the specific adapter required for their system integrations and expansions. Routeco’s online platform emphasizes the convenience of transaction, often providing options for straightforward online purchasing and efficient delivery services. The explicit mention of “next day delivery” further underscores the commitment to timely fulfillment, which is paramount for maintaining project schedules and ensuring operational continuity in demanding industrial environments. This widespread accessibility through authorized distributors like Routeco solidifies the 1769-AENTR’s strong market position as a widely supported and obtainable solution for EtherNet/IP distributed I/O applications. Its consistent presence in specialized product categories ensures it meets the precise needs of engineers and technicians building or expanding CompactLogix systems, reinforcing its role as a standard and reliable component for modern control architectures requiring robust networking capabilities.

Estimated Price: 593,00

The 1769-AENTR EtherNet Adapter has an estimated price point of 593,00. This figure provides a general indication of the investment required for this specific Compact I/O module. It’s important to recognize that such pricing can fluctuate based on various market dynamics, including supplier, regional taxes, shipping costs, and whether the product is new or used. While 593,00 serves as a reported baseline, actual purchase prices might differ. For example, some listings might show individual unit costs, while others could be part of larger system quotes. This price positions the 1769-AENTR within a range typical for industrial automation components that offer crucial networking capabilities, reflecting its specialized function as an EtherNet/IP distributed I/O system adapter. Prospective buyers should always consult current vendor listings, such as those from authorized distributors, to obtain the most accurate and up-to-date pricing information before making a procurement decision. The 593,00 serves as a useful benchmark for budgeting and comparative analysis when evaluating different solutions for CompactLogix systems, highlighting its value in enabling robust communication infrastructure.

Essential Manuals and Documentation

Crucial documentation includes the original 1769-AENTR Installation Instructions, now superseded by 1756 EtherNet/IP Communication Modules (1756-IN050). Further guidance is found in the Compact I/O Modules Installation Instructions (1769-IN088), the CompactLogix 5370 Controllers User Manual (1769-UM021), and the 1769-L35E Compactlogix System User Manual.

Original 1769-AENTR Installation Instructions

The original 1769-AENTR Installation Instructions offered foundational guidance for deploying the 1769-AENTR EtherNet Adapter. This manual detailed physical installation, wiring, and configuration, crucial for Compact I/O module integration. It was the primary reference for EtherNet/IP distributed I/O component requirements and ensuring proper initial functionality. However, these original instructions have been officially superseded. Rockwell Automation has replaced this document with a more current, comprehensive publication: ‘1756 EtherNet/IP Communication Modules, publication 1756-IN050.’ While the original provides historical context on the module’s design, all current installation practices and technical inquiries must now refer exclusively to the superseding manual. This ensures access to the latest information, reflecting product updates and broader system compatibility, essential for modern industrial automation applications and system integrity.

Superseding Publication: 1756 EtherNet/IP Communication Modules (1756-IN050)

The original 1769-AENTR Installation Instructions are no longer the primary reference for this EtherNet adapter. They have been officially replaced by the comprehensive publication, “1756 EtherNet/IP Communication Modules, publication 1756-IN050.” This superseding manual serves as the authoritative guide for a broader range of EtherNet/IP communication modules, including the 1769-AENTR. Its existence implies a standardized approach to documentation for Rockwell Automation’s EtherNet/IP devices, ensuring consistency across different product families and platforms. Users seeking the most current and detailed information regarding installation, configuration, and troubleshooting for the 1769-AENTR should now consult 1756-IN050. This update is crucial for maintaining proper system functionality and adhering to the latest best practices in industrial automation. The 1756-IN050 publication likely covers advanced topics, updated compatibility considerations, and revised procedures that might not have been present in the earlier, product-specific manual. Therefore, reliance on this newer, overarching document is essential for engineers and technicians working with the 1769-AENTR and similar EtherNet/IP communication modules within the Logix platform. It consolidates information, streamlining the documentation process for a wide array of communication components, thereby improving user experience and ensuring compliance with evolving technical standards. This strategic move by Rockwell Automation emphasizes a unified and comprehensive approach to their EtherNet/IP product line.

Referenced Manual: Compact I/O Modules Installation Instructions (1769-IN088)

The “Compact I/O Modules Installation Instructions,” designated as publication 1769-IN088, serves as a crucial foundational manual for anyone working with the 1769-AENTR EtherNet Adapter. While specific communication aspects are covered elsewhere, this document provides essential, overarching guidance for the physical installation of all modules within the 1769 Compact I/O family. It outlines critical procedures such as mounting, power bus connections, and general wiring practices pertinent to the entire series, ensuring proper mechanical and electrical integration. Users are directed to consult 1769-IN088 for details on conductor category information, which is vital for planning conductor routing within a system-level installation. This ensures adherence to best practices for electromagnetic compatibility and reliable operation. This manual complements the adapter-specific instructions by establishing the common framework for the Compact I/O system, making it indispensable for understanding the physical environment in which the 1769-AENTR operates; It provides the necessary context for safely and correctly assembling the 1769-AENTR with other Compact I/O modules, forming a robust and integrated system. Therefore, a thorough review of 1769-IN088 is highly recommended before undertaking any physical setup involving the 1769-AENTR, guaranteeing a solid and compliant installation foundation.

Contextual Manual: CompactLogix 5370 Controllers User Manual (1769-UM021)

The “CompactLogix 5370 Controllers User Manual,” identified as publication 1769-UM021, is a pivotal document for comprehending the operational environment of the 1769-AENTR EtherNet Adapter. While not exclusively detailing the adapter itself, this manual provides comprehensive insights into the controllers with which the 1769-AENTR is designed to integrate seamlessly. It covers the architecture, configuration, and programming aspects of the CompactLogix 5370 controllers, which are fundamental for leveraging the adapter’s capabilities within a larger control system. Understanding the controller’s functionalities, networking capabilities, and system-level considerations, as detailed in 1769-UM021, is crucial for effectively deploying and optimizing the 1769-AENTR as an EtherNet/IP distributed I/O solution. The manual outlines how CompactLogix systems are tailored for low-to-medium level control applications, setting the stage for the adapter’s role in extending I/O. A specific Russian version, 1769-UM021B-RU-P, consisting of 200 pages, further underscores the extensive nature of the information provided. Consulting this manual ensures that the 1769-AENTR is not just installed correctly, but also configured and utilized efficiently within the broader framework of a CompactLogix 5370 control system, maximizing its performance and integration.

Russian Manual Version: 1769-UM021B-RU-P (200 Pages)

For Russian-speaking users, a dedicated version of the CompactLogix 5370 Controllers User Manual is available under the publication number 1769-UM021B-RU-P. This specific manual provides all the critical information found in its English counterpart, but translated into Russian, making technical details more accessible to a broader audience. Spanning an extensive 200 pages, this document offers comprehensive guidance on the operation, configuration, and integration of CompactLogix 5370 controllers, which is directly relevant to understanding the deployment and functionality of the 1769-AENTR EtherNet Adapter. The availability of such a detailed, localized manual is invaluable for ensuring proper system setup, troubleshooting, and maintenance within Russian-speaking regions. It facilitates a deeper understanding of how the 1769-AENTR interacts within the CompactLogix architecture, including wiring, networking, and programming considerations, without the barrier of language. This publication ensures that users can fully leverage the capabilities of their CompactLogix systems, including the EtherNet/IP adapter, by providing clear, unambiguous instructions and contextual information in their native language.

Related User Manual: 1769-L35E Compactlogix System User Manual (149 Pages)

The 1769-L35E CompactLogix System User Manual is a highly relevant document for understanding the operational context of the 1769-AENTR EtherNet Adapter. This manual, comprising 149 pages, offers in-depth information on the 1769-L35E controller, which is a key component within the CompactLogix system family. Since the 1769-AENTR is designed to integrate within these CompactLogix systems, a thorough understanding of the controller’s functionalities, architecture, and system integration principles, as detailed in this specific user manual, is essential. It provides crucial context on how CompactLogix controllers manage and communicate with connected modules, including distributed I/O adapters like the 1769-AENTR, via EtherNet/IP. The manual covers aspects such as hardware installation, module placement, power requirements for the overall system, and basic communication setup. Although it does not focus exclusively on the 1769-AENTR, the document lays the foundational knowledge necessary for successful deployment, configuration, and troubleshooting of the EtherNet adapter within a 1769-L35E-based CompactLogix environment, ensuring optimal system performance and reliability.

Reported Absence of Dedicated 1769-AENTR Manual on RA Site

Users seeking comprehensive documentation specifically for the 1769-AENTR EtherNet Adapter have frequently reported an absence of a dedicated manual on the Rockwell Automation (RA) website. This observation suggests that a standalone, in-depth guide focusing solely on the 1769-AENTR’s unique features, configuration procedures, and troubleshooting specific to the adapter might not be readily available as a primary resource. Instead, individuals trying to understand the module’s full capabilities and compatibility, especially concerning Logix 5000 and CompactLogix processors, often find themselves directed to more general or superseding publications. For instance, the original 1769-AENTR Installation Instructions were replaced by the broader 1756 EtherNet/IP Communication Modules (publication 1756-IN050), and other relevant details are scattered across manuals like the Compact I/O Modules Installation Instructions (1769-IN088) or the CompactLogix 5370 Controllers User Manual (1769-UM021). This necessitates a more diligent approach, requiring users to synthesize information from various sources to gain a complete understanding of the 1769-AENTR’s integration, functionality, and optimal usage within their automation architectures. The lack of a centralized, dedicated manual can extend the learning curve for new deployments and make precise system design more challenging, potentially impacting implementation efficiency significantly.

Installation and Configuration Procedures

Installation requires careful planning for conductor routing, following system-level installation manuals. The assembly process involves integrating the 1769-AENTR Ethernet adapter. Essential Ethernet configuration steps, including setting usernames, are critical for functionality. Refer to Compact I/O Modules Installation Instructions (1769-IN088) for detailed guidance.

Planning Conductor Routing: System-Level Installation Manual

Effective planning of conductor routing is a fundamental step in ensuring the reliable and safe operation of any industrial control system incorporating the 1769-AENTR EtherNet Adapter. This critical phase dictates how power and signal cables are organized, separated, and protected throughout the installation. Adhering to the guidelines detailed within the overarching system-level installation manual is paramount. This manual provides comprehensive instructions and essential conductor category information, which must be meticulously followed during the design and implementation stages. Proper routing minimizes electromagnetic interference, prevents physical damage to conductors, and simplifies future maintenance or troubleshooting efforts. It also ensures compliance with electrical codes and safety standards, which are non-negotiable in industrial environments. Neglecting proper conductor routing can lead to intermittent system failures, reduced data integrity, and even potential hazards. Therefore, prior to any physical assembly with the 1769-AENTR, a thorough review and application of the system-level manual’s conductor routing specifications are absolutely necessary. This meticulous approach guarantees optimal performance and longevity for the integrated Compact I/O system, laying a robust foundation for all subsequent installation and configuration procedures. The system-level installation manual serves as the authoritative guide for this initial, yet crucial, planning phase.

Assembly with 1769-AENTR Ethernet Adapter

The physical assembly of the 1769-AENTR Ethernet adapter is a critical step in establishing a functional Compact I/O system. This process requires careful adherence to manufacturer guidelines to ensure proper operation and system integrity. As referenced, specific details for assembling Compact I/O modules, including the 1769-AENTR, can be found in the Compact I/O Modules Installation Instructions, publication 1769-IN088. This foundational document provides the necessary steps for correctly mounting the adapter alongside other 1769 modules. Typically, assembly involves securing the module to the DIN rail or panel, aligning its bus connectors with adjacent modules, and ensuring a firm connection to the power supply and I/O bus. The 1769-AENTR acts as a bridge, requiring a secure physical link to the CompactLogix backplane to facilitate communication with other I/O modules. Proper module sequencing and spacing are vital to maintain signal integrity and ensure adequate heat dissipation. During assembly, it’s also important to consider the physical routing of conductors as planned, avoiding strain on connections. Unless specifically connected in a particular configuration, the standard assembly practices outlined in the 1769-IN088 manual must be followed for successful integration into the CompactLogix architecture.

Ethernet Configuration Steps

Configuring the 1769-AENTR Ethernet adapter is a vital procedure to establish seamless network communication within a CompactLogix system. This process ensures the adapter can effectively exchange data over EtherNet/IP. While a dedicated 1769-AENTR manual for configuration might be absent on the RA site, the general principles are often covered in broader documentation, such as the 1756 EtherNet/IP Communication Modules (1756-IN050) or the CompactLogix 5370 Controllers User Manual (1769-UM021). Typical configuration steps involve assigning a unique IP address, setting the subnet mask, and defining the gateway for proper network routing. Users often utilize Rockwell Automation software tools to perform these settings, connecting to the adapter to define its network identity. The provided information also hints at parameters like a “Username” during the configuration process, suggesting authentication or access control might be part of the setup. Correct Ethernet configuration is paramount for the 1769-AENTR to integrate properly with Logix 5000 controllers and other EtherNet/IP devices, enabling distributed I/O functionality. Failure to accurately configure these settings can lead to communication errors and system downtime, underscoring the importance of following detailed instructions for successful deployment and operation of the adapter in an industrial control network environment.

System Integration and Compatibility

The 1769-AENTR integrates within CompactLogix systems, compatible with 5370 and Logix 5000 controllers. It is part of the EtherNet/IP adapter family (1734-AENT, 1734-AENTR), enabling diverse Logix solutions for control applications.

Integration within CompactLogix Systems

The 1769-AENTR EtherNet Adapter is a cornerstone for seamless integration within CompactLogix systems, fundamentally enhancing their distributed I/O capabilities. This adapter allows CompactLogix controllers, including models such as the 1769-L23E, 1769-L32E, and 1769-L35E, to communicate effortlessly with remote I/O over an EtherNet/IP network. Its primary function within the CompactLogix architecture is to enable flexible I/O placement, significantly reducing the overall complexity and cost associated with traditional hardwired solutions. By integrating the 1769-AENTR, users can effectively deploy Logix solutions in a wide array of low to medium-level control applications, optimizing system performance and scalability. The adapter forms an essential assembly with the CompactLogix processor, providing a robust communication link that facilitates real-time data exchange. This integration strategy is vital for modern industrial automation, allowing for a more modular and efficient system design. It helps in minimizing I/O spares inventory and simplifying conductor routing, as described in relevant system-level installation manuals. The 1769-AENTR ensures that CompactLogix systems remain adaptable and powerful for demanding control environments, extending the reach and functionality of the central controller.

Compatibility with CompactLogix 5370 Controllers

The 1769-AENTR EtherNet Adapter plays a crucial role in expanding the capabilities of CompactLogix 5370 Controllers, ensuring robust and scalable automation solutions. This adapter is explicitly designed for seamless compatibility, enabling these advanced controllers to integrate distributed I/O effortlessly over an EtherNet/IP network; The synergy between the 1769-AENTR and the CompactLogix 5370 series, which encompasses various models like the 1769-L23E, 1769-L32E, and 1769-L35E, allows for highly flexible and efficient system architectures. Users can confidently leverage the 1769-AENTR to extend the reach of their CompactLogix 5370 system, connecting remote I/O modules and other EtherNet/IP enabled devices without the complexities of extensive point-to-point wiring. This significantly simplifies overall system architecture, reduces installation costs and time, and enhances diagnostic capabilities across the entire network. The detailed compatibility and operational guidance are well documented within the CompactLogix 5370 Controllers User Manual, specifically publication 1769-UM021, which serves as an essential resource for configuration and successful implementation. Implementing the 1769-AENTR with a 5370 controller creates an optimized and highly scalable control system, making it ideal for diverse industrial applications that demand reliable and high-performance EtherNet/IP communication. This powerful combination optimizes operational performance and facilitates advanced modern control strategies, firmly establishing the 1769-AENTR as a cornerstone for distributed control within the Logix platform, acting as a vital communication bridge.

Compatibility with Logix 5000 Controllers

The 1769-AENTR EtherNet Adapter extends its utility beyond just CompactLogix 5370, demonstrating crucial compatibility within the broader Logix 5000 Controllers family. While specifically designed for Compact I/O modules, the adapter’s role as an EtherNet/IP interface enables its integration into more extensive Logix 5000 architectures. This allows Logix 5000 controllers, including ControlLogix processors, to seamlessly access and manage distributed 1769 I/O through the 1769-AENTR. The Logix 5000 platform is renowned for its scalability and versatility, and the 1769-AENTR significantly enhances this by providing a standardized EtherNet/IP communication pathway for Compact I/O. Users benefit from the ability to deploy 1769 modules remotely from the main Logix 5000 controller, optimizing cabinet space and simplifying wiring in diverse applications. Although a dedicated 1769-AENTR manual for direct ControlLogix integration might not be explicitly highlighted on Rockwell Automation’s site, the foundational EtherNet/IP principles ensure interoperability. Information pertaining to Logix 5000 Controllers broadly supports the understanding of how such adapters fit into the overarching control system framework, facilitating efficient data exchange and robust control strategies across the entire Logix 5000 ecosystem. This adaptability underscores the 1769-AENTR’s value in diverse industrial automation setups.

EtherNet/IP Adapter Family: 1734-AENT, 1734-AENTR, 1769-AENTR

The EtherNet/IP adapter family, comprising modules like the 1734-AENT, 1734-AENTR, and the 1769-AENTR, forms a crucial component in modern industrial automation architectures, facilitating distributed I/O communication over EtherNet/IP networks. Each adapter in this family is tailored to specific I/O platforms, ensuring seamless integration and efficient data exchange.

The 1734-AENT and its dual-port variant, the 1734-AENTR, are designed for the Allen-Bradley POINT I/O system. The 1734-AENTR, for instance, is recognized as a Point I/O Dual Port Network Adaptor, providing robust connectivity for the highly modular and compact POINT I/O modules. These adapters allow users to extend I/O capabilities remotely from the main controller, optimizing wiring and panel space.

In contrast, the 1769-AENTR is specifically engineered for the Compact I/O system, often utilized with CompactLogix controllers. It serves as an EtherNet/IP distributed I/O system, enabling CompactLogix processors to communicate with and control 1769 I/O modules over the network. This capability is vital for reducing I/O spares and enhancing system flexibility. All these adapters leverage the power of EtherNet/IP, providing high-speed, reliable communication and simplifying network architectures across various scales of automation applications. Their existence underscores Rockwell Automation’s commitment to versatile and integrated control solutions.

Power Supply Requirements

For proper operation, the 1769-AENTR EtherNet adapter requires specific power supplies. Compatible options include the Allen-Bradley 1769-PA2, 1769-PB2, 1769-PA4, or 1769-PB4 modules, ensuring stable and reliable power delivery for your Compact I/O system.

Required Power Supplies: 1769-PA2, 1769-PB2, 1769-PA4, 1769-PB4

The 1769-AENTR EtherNet adapter, a crucial component for distributed I/O systems, relies on specific power supplies to ensure optimal and reliable operation within a CompactLogix setup. To provide the necessary electrical current and voltage, users must integrate one of the designated Allen-Bradley 1769 series power modules. These include the 1769-PA2, 1769-PB2, 1769-PA4, and 1769-PB4. The selection among these power supplies typically depends on the overall current requirements of the Compact I/O system, including the 1769-AENTR adapter and any connected I/O modules. For instance, the ‘PA’ series generally refers to AC input power supplies, while the ‘PB’ series denotes DC input power supplies, offering flexibility based on the available plant power infrastructure. Each of these power supplies is engineered to seamlessly integrate with the 1769 Compact I/O chassis, providing the regulated power rails essential for the stable functioning of all connected modules, including the adapter’s communication and processing circuits. Proper power supply selection and installation are paramount for system integrity and preventing operational issues, ensuring the longevity and performance of the EtherNet/IP distributed I/O. These dedicated power modules are specifically designed to meet the rigorous demands of industrial automation environments.

Categories: Manuals